EasyManuals Logo

Tektronix TDS2024 User Manual

Tektronix TDS2024
207 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #108 background imageLoading...
Page #108 background image
Reference
TDS1000/2000-Series Digital Oscilloscope User Manual
89
NOTE. The oscilloscope can capture a waveform in normal YT mode
at any sampling rate. You can view the same waveform in XY mode.
To do so, stop the acquisition and change the di splay format to XY.
The controls operate as follows:
H The channel 1 VOLTS/DIV and VERTICAL POSITION controls
set the horizont al scale and position.
H The channel 2 VOLTS/DIV and VERTICAL POSITION controls
continue to set vertical scale a nd position.
The following functions do not work in XY display format:
H Reference or Math waveforms
H Cursors
H Autoset (resets display format to YT)
H Time base controls
H Trigger controls
Help
Push the HELP button to display the Help menu. The topics cover all
the menu options and controls of the oscilloscope. For more
information on the Help system, refer to page ix.

Table of Contents

Other manuals for Tektronix TDS2024

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TDS2024 and is the answer not in the manual?

Tektronix TDS2024 Specifications

General IconGeneral
Channels4
Bandwidth200 MHz
Sample Rate2 GS/s
Record Length2.5k points
Vertical Resolution8 bits
Vertical Sensitivity2 mV/div to 5 V/div
Timebase Range5 ns/div to 50 s/div
Display Resolution320 x 240 pixels
Math FunctionsAdd, Subtract, Multiply, Divide, FFT
Input CouplingAC, DC, GND
Trigger ModesAuto, Normal, Single
Trigger TypesEdge, Video, Pulse
ConnectivityUSB
Input Impedance1 MΩ
Maximum Input Voltage300 V
InterfaceUSB
Power Supply100 to 240 V
Dimensions326 mm x 158 mm x 124 mm