21.12.2 VR Synchronisation
The watchdog daemon is configured in the Local Services->BRRP->VR Synchronisation
menu, i.e. you define how state changes are handled.
After opening the menu Local Services->BRRP->VR Synchronisation a list of all syn-
chronisations is displayed. You can either synchronise virtual interfaces or interfaces. New
synchronisations can be added in the New menu.
For example, you can synchronise both virtual routers R1 and R2 over BRRP. To do this,
you must create two entries. For the first entry, as Monitoring VR / Interface R1 and as
Synchronisation VR / Interface you must use R2. For the second entry, as Monitoring
VR / Interface R2 and as Synchronisation VR / Interface you must use R1.
21.12.2.1 New
Select the New button to create new synchronisations.
Fig. 198: Local Services->BRRP->VR Synchronisation->New
The Local Services->BRRP->VR Synchronisation->New menu consists of the following
fields:
Fields in the Monitoring VR / Interface menu.
Field Description
Monitoring Mode Shows which mechanism is used for monitoring a virtual router.
Possible values:
• =@@:The BRRP-specific state advertisements are used for
determining the state of the master. (The master sends ad-
Teldat GmbH
21 Local Services
bintec Rxxx2/RTxxx2 503