POWER SUPPLY DESIGN
Power Availability And Consumption Table
Power availability
Plixus MME total power supply 500W (400W available for Plixus ports
Plixus AE-R power supply 220W
One single Plixus port allows 100W (engine ports or extension ports)
Maximum power consumption
Confidea F/T 5W
Confidea CS 2W
uniCOS 7" 15W
Plixus NEXT 7W
Lingua Interpreter Desk - Audio only 11W
Lingua Interpreter Desk - Video 12W
Video-IN / Video-OUT box 7W
Confidea WCAP 10W
Maximum distance between units 100m (signal regenerated in every unit)
Minimum required voltage per unit 36V
The general rule states that you should use a maximum 20 delegate units per branch / loop.
Plixus AE-R Power Supply
The Plixus AE-R does not have an internal power supply, however it does have two power connectors. By
default you get one power supply together with the engine. You can extend this power supply with another
as redundancy or when the system requires more power.
To check how many power supplies you require, consult the flowchart shown below.