INSTALL DELEGATE UNITS
Keep at least one meter between two consecutive units to prevent howling effects.
Connect Plixus Units
For all system cable connections use CAT 5e FTP cables with an RJ-45 shielded connector. Plixus units have
an automatic port sensing feature. This means that it doesn’t matter which port is used, the units
automatically detect whether it is an input or output.
Each unit has two conference ports, below you can find a list with all Plixus compatible units and the
location of their conference ports.
Unit type Conference port location
Confidea T Bottom side of unit
Confidea F Built-in part of unit, location may vary depending on the type of unit.
uniCOS Built-in part of unit
Interpreter Desk Back side of unit
Connect To Plixus Engine
After connecting the different Plixus units to each other, connect the branch of units to one of the
conference network ports of the Plixus AE-R, MME or a network extender.
The Plixus AE-R and MME have four conference network ports.
General rule: 80 units can be supported directly by the central unit. However this depends on
type on units , cable sections and length. To calculate the exact amount with the Plixus power
calculator tool.
The central unit can deliver 400 W for external loads (for the Plixus AE-R this is 200W, which
you can increase to 400W with an additional external power supply)
The cable length to the first unit should not exceed 100m.
The cable length between the units should not exceed 100m.