33
stored in a binary file on your PC. You can upload these records from file to TAVL server and
access all the data from TAVL.
TAVL client application lets user to use the following features:
• Import data file saved from the device to the TAVL;
• Preview track of the imported data;
• Generate reports of the imported data.
More details on how to use TAVL application please refer to “TAVL4 application user
manual” documentation or its later versions.
It can be configured to acquire and send data to server. It will be possible to store up to
3854 data records if GSM is not available at the moment. It will send data later when GPRS is
available again. Note that FM3602/FM3612 can have memory full of records. In such a case it will
start deleting oldest records in order to save new ones. Sending all the data records to server
may take some time. Sending 3854 records for
FM3602/FM3612 may take for about 5 hour (exact time may differ depending on GPRS/server
load).
5.8 System settings
System settings have 7 configurable parameters:
• Sleep settings, where user can turn GPS sleep/deep sleep on or off;
• Analog Input Settings, where user can choose analog input range 10 V or 30 V,
depending on needed accuracy (lower range gives higher accuracy of
measurements), and input voltage;
• Object Motion Detection Settings, where user can configure 3 ways how
FM3602/FM3612 will detect stopped movement, and change its working mode (for
working modes, read section 5.13)
• Static navigation settings, where user can turn static navigation on or off;
• Records Settings, where user can enable or disable records when GPS is not
available (no time synchronization);
• GNSS Settings, where user can choose satellite system and GNSS FIX Timeout Time
(if after timeout there will not be synchronized time, it will be synchronized via NTP
server).
• Ignition Source sets ignition triggered functionalities to be triggered by:
o Power Voltage (if voltage is between High Voltage Level and Low Voltage
Level the ignition is considered to be turned on);
o Digital Input (DIN1 ON – ignition on, DIN1 OFF – ignition off);
o Movement (if accelerometer/movement sensor detects movement then
ignition is on, if movement stops – ignition is off).