85
8.6.22.4 AutoGeofence event generating (ID=1104)
Generate event: 0 – on exiting zone, 1 – on entering zone, 2 – on both;
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
2
0
Priority (ID=1103)
AutoGeofence event Priority
(ID=1103)
U8
8.6.22.5 Radius (ID=1105)
Parameter represents radius of circle with center device coordinates after activating
AutoGeofence feature.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1000000
100
Priority (ID=1103)
Deactivate by (ID=1100)
U32
8.6.23 iButton List (ID=7000-7499)
Read 5.4.4.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
FFFFFFFF
FFFFFFFF
-
iButtons list checking (ID 1608)
Deactivate by (ID=1100)
U64
8.7 I/O parameters
I/O properties are additional data sources which are recorded along with usual GPS data.
8.7.1 I/O#1 Priority (ID=2000)
Parameter defines I/O property type of priority: 0 is disabled, 1 – low, 2 – high, 3 – panic.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
3
1
I/O#1 High level (ID=2001)
I/O#1 Low level (ID=2002)
I/O#1 event generation type
(ID=2003)
I/O#1 averaging length (ID=2004)
S8
8.7.2 I/O#1 High level (ID=2001)
Parameter defines high value of triggered I/O property. This parameter is used to set
thresholds for I/O properties to generate events.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
-2147483647
2147483647
1
I/O#1 Priority (ID=2000)
I/O#1 Low level (ID=2002)
S32