TEM A07EXXXX – 1 Unit Transmitters Page 17
4.9 POWER SUPPLY AND TEMPERATURE RANGE
Nominal Operating AC Mains Voltage -------------------------------------------------------------- 230V
AC
±10 %
AC Mains protection fuses ---------------------------------------------------------------------------- 2xT 8 AL 250V
50W Model Line Power ------------------------------------------------------- <120VA @ 50W RF Output Power
100W Model Line Power --------------------------------------------------- <175VA @ 100W RF Output Power
300W Model Line Power --------------------------------------------------- <450VA @ 300W RF Output Power
500W Model Line Power --------------------------------------------------- <710VA @ 500W RF Output Power
Nominal temperature range ----------------------------------------------------------------------------- - -5° to 45°C
Operating temperature range -------------------------------------------------------------------------- -10° to 50°C
Storage temperature range ------------------------------------------------------------------------------ -40° to 50°C
4.10 MECHANICAL SPECIFICATION
1 unit rack 19” --------------------------------------------------------------------------------------- 485x44.4x545mm
10-20-50W model Weight -------------------------------------------------------------------------------------- <6.0Kg
100W model Weight --------------------------------------------------------------------------------------------- <7.5Kg
300W model Weight --------------------------------------------------------------------------------------------- <8.0Kg
500W model Weight --------------------------------------------------------------------------------------------- <8.0Kg