C-20 | Cyber Hardened IBUC 2, IBUC 2e, IBUC 2G, IBUC R, IBUC G Operations Manual: ASCII Command/Response Structure
CSF
Description: Display or configure the IBUC for an input AC frequency of 50/60 Hz.
This command only applies to AC powered IBUCs..
Parameters:
<AC Frequency>
0 = 60 Hz / 1 = 50 Hz
CTI
Description: Display internal 10 MHz source installed..
Parameters:
<Value>
0 = Not Installed / 1 = Installed
Query: CSF
Response: CSF=<AC Frequency>
Command: CSF=<AC Frequency>
Response: CSF=<AC Frequency>
Query: CTI
Response: CTI=<Value>