5-2 | Cyber Hardened IBUC 2, IBUC 2e, IBUC 2G, IBUC R, IBUC G Operations Manual: Monitor and Control Features
Engineered to Endure
4. At the “IBUC Login” prompt enter the username. A default banner will be
displayed followed by the “Password” prompt.
5. Enter the previously defined password. After this step, the user should see the
“IBUC>” prompt.
At this point, one may enter commands from Appendix C, ASCII Command/Response
Structure.
Note:
The Default administrator username/password for a new system is admin/admin. Upon
logging in, the administrator should create a new username/password via command
ADU, described on page C-3. After a successful creation of the new user, the system
administrator should logout from the Terrasat default username, login to the newly
created user and delete the Terrasat username via command DLU on page C-23.
Note:
One might change the current username password via CPS command, described in
detail on page C-19.
Multifunction LED
The multifunction LED is mounted on the Cyber Hardened IBUC 2, IBUC 2e,
IBUC 2G, IBUC R and IBUC G housing and provide visual indications of IBUC
status. LED colors and modes are as follows:
Flashing Green - No alarms
Flashing Red - Minor alarm being reported
Steady Red - Major alarm being reported
Certain alarms are configurable meaning that you define them as major or minor
alarms when thresholds you set are exceeded. Major alarms will cause relay closure
(Form-C). The alarms shown in Table 5.1 are the factory default configuration.
!
CAUTION
Do not delete the default username before creating your new personalized
username.
Do not delete an IBUC user while logged into it.