Page 22
& Press: or until the desired value is selected
ATTENTION: the values range from 0 to 100 daN
& Press: to confirm the selection and move on to the next parameter
or
& Press: to return to the menu without saving any changes made
4.1.3.4 SETTING THE ADC FILTER
♦ Select: MAX DELTA BIT ADC: 10 (or another pre-set value)
corresponds with the maximum difference in bit between two
consecutive readings that the instrument accepts for the reading to
be considered valid. This is used to eliminate peaks or unwanted
interference. The instrument responds more rapidly to load
variations but leads to less stability of the data read when this is set
at low values. The opposite occurs when set at high values
& Press: or until the desired value is selected
ATTENTION: the values range from 1 to 65000 bit
& Press: to confirm the selection and move on to the next parameter
or
& Press: to return to the menu without saving any changes made
4.1.3.5 SETTING THE SAMPLING FREQUENCY
♦ Select: SAMP. FREQUENCY (Hz): 50 (or another pre-set value)
corresponds with the number of readings of the various signals that
are implemented every second. The instrument responds more
rapidly to load variations but leads to less stability of the data read
when this is set at high values. The opposite occurs when set at
low values
& Press: or until the desired value is selected
ATTENTION: the values range from 10 to 50 Hz
& Press: to confirm the selection and move on to the next parameter
or
& Press: to return to the menu without saving any changes made
4.1.3.6 SETTING THE SAMPLES BY AVERAGE ADC
♦ Select: SAMPLES BY AVERAGE: 50 (or another pre-set value)
corresponds with the number of readings with which the arithmetic
mean of the values is calculated.
The instrument responds more rapidly to load variations but leads
to less stability of the data read when this is set at low values. The
opposite occurs when set at high values
& Press: or until the desired value is selected
ATTENTION: the values range from 1 to 50
& Press: to confirm the selection and return to the machine parameter
edit menu
or
& Press: to return to the menu without saving any changes made