EasyManua.ls Logo

Texas Instruments CBL

Texas Instruments CBL
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CBLé System Guidebook 51
Examples: Data Range Setup Instruction
{5,2,1}
5= Data Range Setup command.
2= Retrieve data from
CH2
.
1= Retrieve filtered d/dt (if filter is on)*.
{5,1,0,100,150}
5= Data Range Setup command.
1= Retrieve data from
CH1
.
0= Retrieve filtered raw collected data (if filter
is on).
100= Set Data Begin to 100.
150= Set Data End to 150.
{5,11,3}
5= Data Range Setup command.
11= Retrieve data from
SONIC
channel.
3= Retrieve unfiltered raw collected data
(ignore filter setting)*.
{5,-1}
5= Data Range Setup command.
L1= Retrieve recorded time*.
* Retrieves data from the first to the last sample.

Table of Contents