INS303-5 20/22
Set the user number 1-10 that you want to assign the tag to, using the3.
Address switches, (see chapter 6.2)
Present the tag to the Wiegand reader, an acceptance tone is generated and4.
the tag data is stored in the module for the selected user.
Repeat steps 3 and 4 if other tags are to be learnt.5.
Set Options switch 4 to OFF (Normal Operation), (see chapter 6.2) The6.
status LED will light red when the module is in normal operation.
Set the Door Strike time to the required setting using the Address switches,7.
(see chapter 3.4)
6.5 Stand-alone Mode Operation
When installed in the Stand-alone mode, the operation of the module is as follows:
When a valid tag is presented to the module or via the Wiegand reader you
will hear an acceptance tone from the speaker (if connected) and the internal
sounder (if the Internal Sounder jumper is set to ON). The status LED will
change from red to green and the Door Strike relay is activated for the
selected time (controlled by the Address switches).
When an invalid tag is presented to the module or via Wiegand reader you
will hear an error tone from the internal sounder (if the Internal Sounder
jumper is set to ON). The status LED will momentarily light yellow and the
Door Strike relay is NOT activated.
If the RTE input is activated the Door Strike relay is activated for the selected
time (controlled by the Address switches).
7.0 Specifications
Electrical
Supply: 9 to 14VDC
Current Consumption: 35mA without internal Prox enabled
85mA with internal Prox enabled
Door Strike Relay: Voltage free changeover @3A