INS303-5 13/22
Setup user codes as required then exit the engineer’s mode.11.
Check that the SA840-A20 operate correctly.12.
SA840-A20 Keypad Operation
When the Premier iProx is installed with an SA840-A20 keypad the operation of the
alarm system is as follows:
If a valid user code is entered followed by the [P] key during the exit
sequence the remaining exit time is truncated and the system arms
immediately.
If a valid user code is entered followed by the [P] key whilst the system is
armed, the entry timer is started. The user must enter the premises via the
designated entry route and disarm the system using the standard Premier
remote keypad.
If a valid user code is entered followed by the [P] key whilst the system is
disarmed, the system status is unaffected.
The Door Strike relay is controlled by the control panel and will activate when
the relevant remote keypad output is active.
If the RTE input is activated the Door Strike relay is activated for 5 seconds.
5.0 Installing a Premier Elite External
Prox
The Premier Elite External Prox provides external proximity tag reading capabilities
when used with the iProx module. The figure below shows the connection details: