INS303-5 18/22
Deleting Individual Premier Elite Proximity Tags
If a tag is no longer required it can be deleted from the module as follows:
Set Options switch 3 to OFF (Delete Tag Mode), (see chapter 6.2)1.
Set Options switch 4 to ON (Program Mode), (see chapter 6.2) The status2.
LED will flash red when the module is in program and delete tag mode.
Set the user number 1-10 that you want to delete, using the Address3.
switches, (see chapter 6.2)
Press and hold the tamper switch until the unit generates an acceptance4.
tone.
Repeat step 3 and 4 if other tags are to be deleted.5.
Set Options switch 4 to OFF (Normal Operation), (see chapter 6.2) The status6.
LED will light red when the module is in normal operation.
Set the Door Strike time to the required setting using the Address switches,7.
(see chapter 6.2)
Deleting All Premier Elite Proximity Tags
This procedure offers a fast method of deleting all programmed tags from the
module:
Set Options switch 3 to OFF (Delete Tag Mode), (see chapter 6.2)1.
Set Options switch 4 to ON (Program Mode), (see chapter 6.2) The status2.
LED will flash red when the module is in program and delete tag mode.
Set all Address switches to OFF.3.
Press and hold the tamper switch, after 3 seconds the unit will start to beep4.
every second. After 10 seconds the unit generates an acceptance tone and
all tags are deleted.
6.4 Using 3rd Party Proximity Tags
This configuration allows you to use proximity tags from other manufacturers. The
proximity reader MUST be capable of providing the data in 26bit Wiegand format.
The figure below shows a typical installation: