the control panel will start the exit sequence. The exit tone will be generated
if the “Sounder Enabled” switch 3 is ON. The user should leave premises as
normal. If the alarm system is armed or in entry mode the system will disarm
on presentation of a valid tag.
When an invalid proximity tag is presented to the module or via the Wiegand
reader you will hear a beep from the internal sounder (if the Internal Sounder
jumper is set to ON). The status LED will momentarily change from green to
yellow, but the status of the alarm is not affected.
The Door Strike relay is controlled by the control panel and will activate when
the relevant remote keypad output is active.
If the RTE input is activated the Door Strike relay is activated for 5 seconds.
N To restrict operation of the iProx to door strike please see the control panel
installation manual.
4.0 Using the Key Seven SA840-A20
Keypad
This configuration allows you to integrate the SA840-A20 keypad manufactured by
Key Seven with the Premier Elite 24/48/88/168/640 control panels. The figure
below shows a typical installation: