INS884EN-4 63/87
WiFi connections: ComIP address should be 000.000.000.000.
Ethernet connections: ComIP address should be as per LAN IP, e.g.
192.168.001.020.
Check that Texecom Connect ARC is correctly configured.
UDL/Digi Options > Program Digi > ARC 1 Protocol > Texecom Connect
Pri No: 127.0.0.251
Sec No: blank
Account No: blank
Dialling Attempts: Set as required (09 attempts by default)
Report Areas: Set as required (all areas by default)
Reports: Set as required (PAO*MTC* by default)
Config 1: * * * * * * I * (Connect via IP)
Config 2: * 2 * P (Com Port 2 & Add Push)
These configuration settings are automatically populated when Texecom Connect
is selected as the protocol for the ARC.
To automatically repopulate these settings:
Program ARC Protocol as ‘Disabled’;
Reprogram ARC Protocol as ‘Texecom Connect’.
NOTE: Com Port settings must be programmed first for the ComIP port to be
automatically identified within the ARC configuration.
Error Message: NO CARRIER / NO CON