initialR2T
InitialR2T is a setting that only really matters over high-latency WAN connections
and perhaps in some exotic situations with synchronous writes to very, very fast
storage.
iSCSI CRC/Checksum
To enable this option, the initiator can connect with “Data digest” and “Header
digest”.
Emulate Write Cache
To enable this option, the performance will increase. .
Modify/Remove iSCSI Target
To modify or remove iSCSI target on the current RAID volume, follow the steps
below:
1. Under the iSCSI List, click on desired iSCSI volume you like to modify or
remove.
2. Click on Edit and associated screen will appear.
3. Click on Remove Target to remove it or make necessary change then
press Apply to confirm.