4. Select from unused disk then click OK, the system will bring up available
options to choose from.
5. Confirm the setting, then system will begin migrate the RAID volume.
Here is a list of limitation with RAID level migration function:
1. During RAID level migration, it is not permitted to reboot or shutdown
system.
2. For RAID migration from R1 to R5 or R1 to R6, all services will restart
and “iSCSI” volume will be in read only mode but read/write of the “user
data” will be possible during the operation.
Below is a table listing of possible RAID migration schemes:
To
From
RAID 0
RAID 5
RAID 6
NOTE
Migrating a RAID volume could take several hours to complete
The RAID migration feature is available only when it is
configurable.
NOTE
The migration scheme below is based on Thecus
IP Storage product’s maximum possible
combination. For other model which supports less
HDD, please refer to the web UI while RAID
migration operates.