SERVICE 5-4 Manual 0-2888
B. Check Optional Single - Stage Filter Element, replace if necessary.
1. Shut off input power.
2. Shut off air supply, bleed down system.
3. Disconnect gas supply hose from filter.
4. Turn the Cover counter - clockwise.
5. Remove the Filter Element from the Housing and set Element aside to dry.
6. Wipe inside of housing clean, then insert the replacement Filter Element open side first.
7. Replace Housing on Cover.
8. Reattach gas supply hose. If unit leaks between housing and cover, inspect the "O" Ring for cuts or other damage.
A-02476
Filter
Element
(Cat. No. 9-7741)
Housing
Cover
Barbed
Fitting
Spring
Assembled Filter
O-ring