Main Menu
109
2. Press the F4 ENTER KEY to expand this menu.
3. Press the F2
OR F3 UP/DOWN key to scroll through submenu until [TRIP START] appears in display.
4. Press the F4
ENTER KEY to enter Trip Start function. The date and time of the last trip start appears in
the screen.
5. Press the F4
ENTER KEY again to enter a new start of trip date and time in the log.
NOTE: When a PTI test is completed, the controller automatically enters a Trip Start in the log.
6. Press the F1 key to exit the Commands menu.
Set Log Time Interval
With the UNIT TURNED ON Allow Unit to start and stabilize and the Display showing the unit status
display (setpoint):
1. Press the F4 M
ENU key. Press the F3 key to scroll down to the DATALOGGER Menu.
2. Press the F4
ENTER KEY to access the Datalogger menu.
3. Press the F2
OR F3 UP/DOWN key to scroll through submenu to [SET LOG TIME INTERVAL]
4. Press the F4
ENTER KEY to enter Temp Log. Display shows the current Log Time interval.
5. Press the F4
ENTER KEY again with cursor in [LOG TIME] menu line to enter a new log interval.
[ARROW] appears in menu line.
6. Press the F2
OR F3 UP/DOWN key to increase or decrease the Log Interval.
*The logging of USDA sensors is fixed at 1 hour intervals to comply with USDA requirements. A
logging test of USDA sensors at 1 minute intervals is possible for 72 minutes. USDA data can not be
downloaded during the logging test and can only be viewed on screen. After 72 minutes, controller
returns to previous logging interval and clears USDA test data from data logger memory.
7. When the correct Log Time appears in the menu line, press and hold the F4
ENTER KEY until cursor
stops flashing. The new Log Time appears in the display.
8. Press the F1 key to exit.