Controller Description
46
Software Version 2.3.7.0 110608
Release Date New Features
June 10, 2011 MTS and CT Feature Selectable
MTS and CT must be selected through the CONFIGURATION/OPTIONS menu, “MTS
FEATURE ON/OFF” oCT FEATURE ON/OFF”. CT is not allowed with OOCL prefix.
MTS Feature Selects Present Set Point
MTS feature will now select the present set point as first set point and not the last MTS set
point.
USDA Trip Defaults OFF
When all the USDA sensors are removed from unit, the USDA feature will default to OFF.
Dehumidify Improvement
Unit running dehumidify the evaporator fans will change momentarily from low to high
every hour, to blow water off coil
Battery Heater Disabled
If battery sensor errors battery heater will be disabled.
Compressor Temperature Reading
Compressor sensor reading returns to the data menu.
Heating Element Type
Heating element type has been added to CONFIGURATION/UNIT CONFIG menu. Units
with 3 heaters show “EXTENDED CAPACITY” unit with 6 heaters show “NORMAL
CAPACITY”.
C to F or F to C Display Change
Press the C/F key to change the display from C to F or F to C, if another key is pressed or
display returns to main display, display will return to original C or F.
To permanently change the display from C to F or F to C, press and hold the C/F key.
Message will appear ARE YOU SURE? Select YES or NO to change.
Permanent display change not allowed with OOCL or HL prefix
Viewing Event or Temperature Logs in Display
Now can select under DATALOGGER/INSPECT LOGS. INSPECT EVENT LOGS,
INSPECT TEMPERATURE LOGS, INSPECT SMART LOGS (Event/Temp logs together)
on main power or battery power.