*: The wind reference can be set in the MWV telegram by means of DIP
switches 5
and 6 (refer to chapter 7.3 and 7.4).
5:
6:
With its special identification, the following telegram is intended for the
„weather
display“, and includes the air pressure in hPa.
$WIMWV,ddd,R,ss.s,M,A*HL<CR><LF>
Value wind velocity in m/s
Unit: m/s
R = relative wind / T = true wind *
Value wind direction in degrees
Status: A=valid data, V=invalid data
$WIMWD,ddd.d,T,,M,sss.s,N,sss.s,M,A*HL<CR><LF
Value rel. wind velocity in m/s
Value
T = true wind
Value rel. wind direction in degrees
Status: A=valid data, V=invalid data
$THIES,aaaa.a,*HL<CR><LF>
Air pressure in hPa