E14
WT “FF.F” Wind speed error in the telegram (for ex. Ultrasonic).
E15
WD “FFF” Wind direction error in the telegram (for ex. Ultrasonic).
E16
REL/TRUE error
Check transmitted protocol (error „a“ appears twice in telegram).
E17 VDT protocol
No reception from ultrasonic
- check connection (RS485 half-duplex).
E20 *
COM 3
Timeout
Timeout, no reception.
E21 * COM 3 error 1.Check Baud rate settings.
2.Check R422 connections/lines Rx+ & Rx-.
E22 * LOG error
(velocity)
No valid velocity values available in telegram.
Check protocol(s).
E23 **
COM 2
Timeout
Timeout, no reception.
E24 **
COM 2 error 1.Check Baud rate settings.
2.Check R422 connections/lines Rx+ & Rx-.
E25 **
Gyro error
(heading)
No valid heading values available in telegram.
Check protocol(s).
E50
Syntax error Device faulty: Restart, if necessary.
E99 Watchdog
Temporary interference, if a nonrecurring error message appears
for 3sec.
If error message appears frequently, device faulty.