Rev E TR-220 90 008 088-1
2-54
Close the Program. You have not created a permanent short cut configured for
the TR-220 RS-232 download feature. You will not be required to repeat this
procedure. When preparing to download data, select the TR-220 Hyper Terminal
that should be located within the Hyper Terminal program selection dropdown.
2.19.2 Downloading the Data
Ensure the Test Set is OFF before connecting the Test Set to your computer.
1. Connect a standard RS-232 extension cable (not supplied) to the RS-
232 connector located on the front panel of the Test Set and connect the
other ends to the COM Port that was selected paragraph 2.15.1 step 7
(typically COM1).
2. On the computer, select the TR-220 Short Cut that was created in the
paragraph 2.15.1.
3. Select TRANSFER from the Hyper-Terminal drop down menu.
4. Select CAPTURE TEXT and save the file to your desktop
(recommended) and name the file to your preference but utilize a .csv
extension (for example - Serial Number 2345Date.csv). Select START.
5. Press the MANUAL toggle switch on the Test Set to begin
downloading the data and observe the following:
The data will download to the Hyper-Terminal program and can then be
observed on the computer display. Once all of the data has been
transferred, the Test Set will indicate:
Select TRANSFER on the Hyper-Terminal drop-down menu, then
CAPTURE TEXT and STOP. The data is now saved to the file. The
operator may now choose to erase the stored data on the Test Set by
toggling the MANUAL switch on the Test Set. Simply turn the Test Set
OFF if you desire to keep the file in the memory.
6. Turn OFF the Test Set and disconnect the RS-232 cable.
TEL-INSTRUMENT
Transferring Data . . .
Output Completed
Press MAN To Erase