Compact IP Codec User's Manual
57
Techno Mathematical Co., Ltd.
2140P
Appendix
1
. Errors and Warnings
Errors
Number
Log Output Description Required Action LED Transition
E-001 E001:Parameter Error Though incorrect
parameter settings are
normally not possible to
set on the setting screen,
an incorrect parameter
was discovered when
actual transmission
started.
The problem parameter
will be shown on the
display, so review the
settings of the applicable
parameter and its related
parameters.
The LED goes out when
the correct setting is
configured and the
output is started.
E-002 E002:FileWriteErr Writing to built-in flash
memory failed.
If writing is not possible
after three retries,
contact TMC support.
At any point when
writing is not
successful for the first
three times, the LED
transitions as follows:
Lit 5 seconds -> Unlit.
E-003 E003:GBT Not Detect Image port cannot be
detected.
Contact TMC Support. LED lit only (does not
go out).
E-004 E004:Panel Con. ERR Panel communication
error (remote screen and
log only)
Contact TMC Support. LED lit only (does not
go out).
E-005 E005:AES Not Detect AES devices not
connected to and AES
compatible device.
Connect the AES device
correctly.
Goes out upon AES
device connection.
E-100 E100:Connect Err Could not connect to
encoder. (During user
authentication)
Check the password.
Check the connection
destination Tx IP
address, channel number,
etc.
Confirm that there are
fewer than 20 connection
destination Tx connected.
(On encoder)
Goes out upon
connection.
E-101 E101:Tx Discon Disconnection of line
with the encoder.
Connect a different
encoder.
Change to the line
disconnection support
mode, and then connect
the line again.
In the case of a line
disconnection support
mode, connecting to the
set encoder will cause
error LED to go out and
the warning LED to
light. Warning LED
goes out upon
connection.
E-103 E103:Miss Encrypt Key Could not obtain
encryption key.
LED lit for five seconds,
then goes out.