EasyManua.ls Logo

TMC TM7006E - Page 60

Default Icon
66 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Compact IP Codec User's Manual
59
Techno Mathematical Co., Ltd.
2140P
Warnings
Number
Log Output Description Required Action LED Transition
W-002 W002:Log File Over Log file exceeds 100
MB.
Nothing in particular LED lit, goes out by
log clear.
W-010 W010:Rx Ilg. Dis-con. The decoder
disconnected from the
line without following
the proper
disconnection process.
(Disconnection: Packet
report packets could
not be received within
an interval of at least
10 packets while there
was no decoder
disconnect request.
Nothing in particular Goes out at the time
when packet
transmission from the
encoder stops.
W-101 W101:Wrong PWD Mismatch with the
registered user
password.
All information is
registered in log output,
so check log output.
LED lit for five
seconds, then goes out.
W-102 W102:MAX RX OVR The 20-unit maximum
allowable number of
decoder connections
was exceeded.
Reduce the number of
decoder connections
LED lit for five
seconds, then goes out.
W-103 W103:RTC Cnt. Unmatch
The rate control
ON/OFF settings of
the encoder and
decoder are different
(when UniCast and
encoder are ON).
Configure correction
connection settings.
(User operation standby)
LED lit for five
seconds, then goes out.
W-112 W112:Not Found Tx During normal
connection, the
connection destination
does not exist (channel
number, channel
name, IP address, and
other information).
Re-connect to a proper
connection destination.
However, note that
connection is abandoned
and requesting is
stopped if there is no
connection after three
tries.
LED lit for five
seconds, then goes out.
W-200 W200:Preset No Apply During rate control,
preset settings and
parameter changes
have no effect.
However, presets are
used for transmission
after rate control is
ended.
Nothing in particular LED lit for five