12
Introduction
• Attribute•Measurement step display
Displays the backsight and foresight (in Height difference, Setting
out, or Measuring elevation modes).
: Backsight
: Foresight
Displays the attribute of the recorded measurement value (Height
difference measurement mode, Elevation measurement mode).
: Backsight point
: Foresight point
: Intermediate sight
: Fixed point
:Off
Displays the measurement step (when Adjustment is selected in
the Configuration mode).
At position A
: Take a reading on staff a.
: Take a reading on staff b.
: Take a reading on staff a with the tripod turned 180°.
: Take a reading on staff b with the tripod turned 180°.
At position B
: Take a reading on staff a.
: Take a reading on staff b.
: Take a reading on staff a with the tripod turned 180°.
: Take a reading on staff b with the tripod turned 180°.
Displays the page number of the active menu (when the Menu
mode or Configuration mode is selected).
:First page
: Second page
• Measuring mode (not displayed on menu screens)
Displays the currently selected measuring mode.
: Single measurement
: Average measurement
: Wave-and-Read measurement
: Repeat measurement
: Tracking measurement
DL502-503.book 12 ページ 2010年4月5日 月曜日 午前9時47分