9168 Control Box
P/N 7010-0781
7-9
9168 Control Box
This section lists possible 9168 control box problems you may
encounter. If you still have problems after trying the solutions listed
here, contact TPS customer support.
Problem
Control box does not power on.
Causes Solutions
The cable is the wrong
cable, incorrectly
connected, or
damaged.
Check that the power cable supplies 12 to
24 VDC and is negative conductive.
A socket (positive) = 12 to 24 VDC
E socket = Ground
Check that the power cable is connected to
the correct port (“Connectors” on page 3-8)
and see that the ends are securely fastened.
If the cable is damaged, contact your dealer
to purchase a new cable.
Problem
Screen display turns off by itself.
Causes Solutions
The fan may be
damaged, causing the
control box to
overheat.
Check that the fan is rotating.
If the fan is not rotating, it may be damaged
and needs to be replaced with new one.
Contact your dealer.
Contact your dealer for information on
replacing the fan.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Topcon mmGPS 3D Paver and is the answer not in the manual?

Topcon mmGPS 3D Paver Specifications

General IconGeneral
BrandTopcon
ModelmmGPS 3D Paver
CategoryControl Systems
LanguageEnglish

Related product manuals