4. ON-DEMAND REMOTE CONTROL FUNCTIONS
The time limit for Turning is 60 seconds from the start of Turning operation. If the operation exceeds
this time limit, an error occurs.
When Auto Tracking has been selected, the total station will start tracking a moving prism once
Turning to that prism has been completed.
This section explains the measurement procedure for a single operator working from the Remote
Controller. An operator working alone will need a data collector (available as an optional accessory).
When reflected laser signal is strong (object with high reflection factor):
If there is an object with a high reflection factor, such as a window or standing water, in the vicinity
of the total station/prism, the laser beam may be reflected and Turning operation performed pointing
at the object instead of the Remote Controller. In this case the accuracy of measurement results may
be adversely affected.
Fix the pole vertically over the measurement point.
For communication settings for data collectors etc., see the operator’s manual for your respective
device.
PROCEDURE
1. Connect the instruments.
"5. SYSTEM CONFIGURATION"
2. Switch ON the power to the total station and
the total station should be ready to Bluetooth
communication.
4.2 Measurement Flow