Instructions for Use TORMAX 1102, 1201 T-1661 e 11
Traffic Control
Movement through the door can be allowed in only one direction if desired (operating mode EXIT) or
completely blocked (operating mode OFF).
Double-leaved systems can also be operated as single leaf doors by means of the single leaf operation
switch.Inthiscasebothdoorscanonlybeopenedbymeansofthekeyswitchorthe“bedmovement”
switch.
Automatic System Monitoring
The control system monitors the safety sensors by a cycle of active tests. The control system also
conducts continuous internal system tests. If a safety-related component should fail, the system auto-
matically switches into a safe condition. At the same time the fault number is displayed on the user
interface. The operating mode currently displayed also flashes. You can find further information on this
subjectinsection5“ProcedureintheEventofaFault”.
Economy power mode
Economy power mode is activated as standard. This mode consumes less power in the non-operative
state.
The illumination on the user interface and most sensors are automatically switched off when not in use.
Electric Lock u
The system can be locked in the closed position by means of an electric lock u.
Operation in the Event of a Power Failure
Depending on the equipment installed, the following functions are possible:
– Controlled closing using the integral spring. The door can be opened manually by means of the
door handle (unlocking).
The door then closes again in a controlled manner using the integral spring.
The closing sequence is maintained in double-leaved doors by the use of a mechanical door coor-
dinator.
– Controlled opening using the integral spring. The door remains open.
– Continued operation for a certain period in the current operating mode by means of a battery unit u.
– Unlocking and opening of the door from outside by means of a key switch and the battery unit u.