EasyManuals Logo

Tormax 1102 User Manual

Default Icon
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
18 Instructions for Use TORMAX 1102, 1201 T-1661 e
6 Maintenance
The system was tested and approved by a skilled person before initial commissioning. The manufac-
turer recommends that you conclude a service contract in order to maintain the value of your system
for as long as possible as well as to ensure the system operates reliably and safely for a long time.
Only genuine TORMAX spare part should be used. The manufacturer accepts no liability if you fail
to observe this requirement. Original spare parts and original accessories guarantee the safety of
use in accordance with norm EN 16005.
The following maintenance work must be carried out:
6.1 Cleaning
Warning
Closing doors can crush – danger!
Trapped limbs can lead to serious injury.
• ThesystemmustonlybecleanedinoperatingmodeOFF,OPENorManualOperation.
• Cleancasingparts,theuserinterfaceanddoorleaveswithadampclothanda
commercial cleaner.
6.2 Functional Checks
The operator must check the function and safety devices of the automatic swing door at least
every three months. This will ensure that faults or hazardous changes in the system are detected
atanearlystage.Seesection7.2“Check-listforFunctionalChecks”foritemstobechecked.
You should arrange for any defects detected during the routine checks to be rectified immediately by
a TORMAX dealer (see the last page of this Manual for the address).
Warning
Potential switching malfunction in the automatic swing door.
Potential hazards – injury caused by impact or crushing.
6.3 Maintenance and Testing
Maintenance and testing should only be carried out by a trained skilled person following the manufac-
turer’s instructions.
Maintenance Interval
The maintenance interval depends on the frequency of use but the system must be maintained at
least once per year.
Scope of the Maintenance Work
The content of the maintenance work is specified by the manufacturer in an inspection list.
System Test Book
The test findings are recorded after the test in the system test book. The operator must keep it in a safe
place.