16 Instructions for Use TORMAX 1102, 1201 T-1661 e
Parameters for displays
012 Drivetype(1=1102,2=1201)
042 Firmware version
043 Number of cycles
044 Number of operating hours
Parameters for settings
10 0…E Hold open time for activator inside / outside
0 / 1/ 2 / 3 /4 / 5 / 6 / 8 /10 /12.5 /15 /17.5 /20/40/ 60 s11 0…E Hold-open time button e.g. for beds
12 0…E Hold-open time for key switch
13 0…9
Delay for operating mode OFF (selection via
user interface)
1/ 3 /5 / 7.5 /10 /15 /20 /30 /45 / 60 s
14 0…9 Bell active time 0 / 0.5 / 1 / 2 / 3 / 4 / 5 / 6 / 8 / 10 s
20 0…6 Opening speed
10 … 100 %
21 0…6 Closing speed
30 1…3/6 Power limit when opening
Maximum depends on the drive type
31 1…3/6 Power limit when closing
32 1…3/6
Power limit when closing before the door is
closed
38 0…6 Starting angle for Push & Go / Power Assist 1/ 2 / 3 / 5 / 8 / 12 / 16 degrees
39 0…5 Starting angle for Push & Close Maximum / 8 / 10 / 12 / 14 / 16 degrees
80 0…2 Bell trigger Activator outside / activator inside / key switch
81 0…4 Button press time (detection delay for activator) 0/1/2/3/5
91 0…4 Code lock for user interface Switched off / code 111/... 222 /… 333 /…123
Command
040 Software reset
4.4 Operation with an Operating Mode Switch u
Selection of Operating Modes
The switch position defines the operating mode.
T1305_4
OFF
AUTOMATIC
OPEN
Resetting the System
– Change the operating mode in the event of a fault
or
– Cut off power supply to the system for at least 5 seconds.