20 Instructions for Use TORMAX 1102, 1201 T-1661 e
System Behaviour No. Cause Remedy/ Rectification
The door remains open E45 Emergency opening is active for
>1minute
Reset the command from the higher
ranking system.
The door remains closed E46 Emergency closing is active for
>1minute
Reset the command from the higher
ranking system.
The door remains closed E47 Blocking switch active for
>1minute
Reset the command from the higher
ranking system.
The door remains open E48 ”Beds“sensoractivefor>1minute. Resettheswitchfor“passagewith
beds”.
The door stands still E51 Anomaly in the travel distance.
Solid obstruction in the movement
area.
Remove firm obstacle in the travel-
ling range of the door.
Perform a software-reset.
The door stands still E61
E62
E63
Power supply is overloaded or volt-
age too low.
Get the power supply and connec-
tions checked by a skilled person.
The door stands still E64 Drive/control system is overheated. Wait for the automatic reset after
the door/control system has
cooled.
Protect from direct sunlight.
The door stands still E66 Motor or output stage defective. Wedge the door open in the open
position or disengage the linkage.
Switch off the power supply.
Arrange for the system to be re-
paired by a specialist.
The secondary door leaf
remains motionless.
E99 Fault on the secondary drive. Arrange for the system to be
checked by a specialist.
The door stands still. E..
E0..
E2..
Control system shut down for
safety reasons.
Perform a software-reset.
Arrange for the system to be re-
paired by a specialist.