Premaintenance
Procedures
DisconnectingtheBattery
Beforeperformingmaintenanceonthemachine,disconnect
themachinefromthebatterypackbypullingtheT-handle
connectoroffofthemainpowersupplyconnector.
G017237
1
2
Figure37
1.T-handleconnector2.Mainpowersupply
connector
Lubrication
GreasingtheMotorCoupler
ServiceInterval:Yearly
GreaseType:General-purposegrease.
1.Turnoffthemachineanddisconnectthebatterypack.
2.Removethe2boltssecuringthemotortothe
transmissioncase(Figure38).
1
2
3
4
G017383
Figure38
1.Coupler—female
3.Bolt
2.Motorshaft
4.Electricmotor
3.Pullthemotoroutandawayfromthetransmission
case.
4.Addonetotwopumpsofgreasefromagreasegunto
thefemalecouplerinthetransmissioncase(Figure38).
5.Installthemotorandsecureitwiththe2boltsremoved
previously.Torquetheboltsto29to33N-m(21to
25ft-lb).