EasyManua.ls Logo

Toro 30881 - Page 174

Toro 30881
347 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Groundsmaster 4500 --D/4700--DHydraulic S ystem Page 4 -- 134
Lift Control Manifold Service (GM 4500--D)
1. Manifold body
2. Proportional relief valve (port TS)
3. Solenoid valve (port S6)
4. Solenoid coil (2 used)
5. Check valve (port CV)
6. Orifice (0.080)
7. Zero leak plug (#4)
8. Nut
9. Straight fitting
10. O--ring
11. Nut
12. O--ring
13. Relief valve (port RV)
14. Solenoid coil
15. Nut
16. Solenoid valve (port S5)
Figure 113
13
7
14
4
6
10
3
11
12
2
1
5
16
15
9
8
7
4
5ft--lb
(6.8 N--m)
5ft--lb
(6.8 N--m)
20 ft--lb
(27 N--m)
20 ft--lb
(27 N--m)
25 ft--lb
(34 N--m)
20 ft--lb
(27 N--m)
20 ft--lb
(27 N--m)
5ft--lb
(6.8 N--m)
25 ft--lb
(34 N--m)
25 ft--lb
(34 N--m)
UP
NOTE: The ports on the lift control manifold are marked
for easy identification of components ( e.g. P is the sup-
ply connection port and R7 is the location for the lift relief
valve). See Hydraulic Schematics in Chapter 9 -- Fold-
out Drawings to identify the function of the hydraulic
lines and cartridge valves at each port location.

Table of Contents

Other manuals for Toro 30881

Related product manuals