EasyManua.ls Logo

Toro Groundsmaster 3280-D - Testing the Steering Circuit-Steering Control Valve, Relief Valve Pressure, and Steering Cylinder (Machine Serial Numbers above 316000000)

Toro Groundsmaster 3280-D
508 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TestingtheSteeringCircuit–SteeringControlValve,ReliefValve
Pressure,andSteeringCylinder(MachineSerialNumbersabove
316000000)
g224913
Figure71
Unitsteeringperformancewillbeaffectedbyincorrectreartirepressure,binding
inthehydraulicsteeringcylinder,extraweightonthevehicle,and/orbindingof
thesteeringforks.Ensurethattheseconditionsarecheckedandfunctioning
properlybeforeproceedingwithanysteeringsystemhydraulictesting.
Note:Thereliefvalveforthesteeringcircuitisintegratedintothesteering
controlvalve.
TestProcedure
1.Ensurethatthehydraulicuidisatnormaloperatingtemperatureby
operatingthemachineforatleast10minutes.
2.Drivethemachineslowlyinagureeightonaatlevelsurface.
HydraulicSystem:TestingtheHydraulicSystem
Page5–66
Groundsmaster
®
3280-D/3320