EasyManua.ls Logo

Toro Groundsmaster 3280-D - Page 240

Toro Groundsmaster 3280-D
508 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GeneralRunandTransportProblems
Problem
PossibleCauses
Theenginecontinuestorun,butshouldnot,whenthekey
switchisturnedtotheOFFposition.
Thebatteryisdischarged.
Thebatterycablesarelooseorcorroded.
ThefuseF1-1(15A)tothekeyswitchisdamaged;refer
toFuses(MachineSerialNumberbelow400000000)(page
6–22)orFuses(MachineSerialNumberabove400000000)
(page6–23).
Thekeyswitchorcircuitwiringisdamaged.
Theengineshutsoffduringtheoperation,butitisableto
startagain.
Note:Iftheexcessivecoolanttemperaturecausesthe
enginetoshutdown,theoperatorcanstarttheengineby
movingthemachinetoashortdistance.Afterstartingthe
engineinthiscondition,theenginerunsforapproximately10
secondsbeforeitshutsoffagain.
Theparkingbrakeisengaged.
Theoperatorisraisingfromtheseat(theseatswitchnot
fullypressed).
Theseatswitchorcircuitwiringisdamaged.
Thekeyswitchorcircuitwiringisdamaged.
Themachineisoperatedonaslopewithalowfuellevel.
Theparkingbrakeswitchorcircuitwiringisdamaged.
Theenginecontinuestorun,butshouldnot,whenthe
tractionpedalispressedwithnooperatorontheseat.
Theseatswitchisdamaged.
Theseatswitchwiringisloose,corroded,ordamaged.
Thetractionneutralsensorisoutofadjustmentordamaged.
Theengineshutsoffwhenthetractionpedalispressedor
thePTOswitchisONwiththeoperatorintheseat.
Theoperatorisraisingfromtheseat(theseatswitchnot
fullypressed).
Theparkingbrakeisengaged.
Theseatswitchisdamaged.
Theseatswitchwiringisloose,corroded,ordamaged.
Theenginecontinuestorun,butshouldnot,whenthePTO
switchisONwithnooperatorintheseat.
Theseatswitchisdamaged.
Theseatswitchwiringisloose,corroded,ordamaged.
Thetractionneutralsensorisoutofadjustmentordamaged.
ElectricalSystem:Troubleshooting
Page6–12
Groundsmaster
®
3280-D/3320
05138SLRevB

Table of Contents

Other manuals for Toro Groundsmaster 3280-D

Related product manuals