IdenticationandFunction(continued)
F2-2(20A)(Ifequipped):Protectspowersupplytotheoptionalaccessory.
F2-3(20A)(ifequipped):Protectspowersupplytotheoptionalaccessory.
F2-4(20A)(ifequipped):Protectspowersupplytotheoptionalaccessory.
TestingtheFuses
1.TurnthekeyswitchtotheONposition(donotstarttheengine)andremove
thecontrolpanel.Withthefuseinstalledinthefuseblock,useamultimeter
tocheckthat12VDCexistsatbothoftheterminaltestpointsonthefuse.
If12VDCexistsat1ofthefusetestpointsbutnotattheother,thefuse
isdamaged.
2.Ifnecessary,removethefusefromthefuseblockfortesting.Thefuseshould
havecontinuitybetweenthefuseterminals.
A.EnsurethatthekeyswitchisintheOFFpositionandthekeyisremoved
fromthekeyswitch.
B.Locatethefuse(s)tobetestedunderthecontrolpanel.
C.Removethefuse(s)fromthefuseholderfortesting.Thefuseshould
havecontinuitybetweenthefuseterminals.
IMPORTANT
Iffusereplacementisnecessary,ensurethatreplacementfuse
hasthecorrectamprating.
D.Replacethefuseiftestingdeterminesthatitisdamaged.
E.Afteryoucompletethefusetesting,installthecontrolpanel.
ElectricalSystem:TestingtheElectricalComponents
Page6–24
Groundsmaster
®
3280-D/3320
05138SLRevB