EasyManua.ls Logo

Toro Groundsmaster 360 - Page 41

Toro Groundsmaster 360
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.TheInfoCenterdisplaystheINITIATINGDPF
REGENmessage(Figure56).
g224411
g227681
Figure56
6.TheInfoCenterdisplaysthetimetocomplete
message(Figure57).
g224406
g224406
Figure57
7.Theenginecomputercheckstheenginestate
andfaultinformation.TheInfoCentermay
displaythefollowingmessagesfoundinthe
tablethatfollows:
CheckMessageandCorrectiveActionTable
CorrectiveAction:Exittheregenerationmenuandrunthe
machineuntilthetimesincelastregenerationisgreaterthan
50hours;refertoTimeSinceLastRegeneration(page34).
CorrectiveAction:Troubleshoottheenginefaultandretry
DPFregeneration.
CheckMessageandCorrectiveActionTable
(cont'd.)
CorrectiveAction:Startandruntheengine.
CorrectiveAction:Runtheenginetowarmthecoolant
temperatureto60°C(140°F).
CorrectiveAction:Changetheenginespeedtolowidle.
CorrectiveAction:Troubleshoottheenginecomputer
conditionandretryDPFregeneration.
8.TheInfoCenterdisplaysthehomescreenand
theregenerationacknowledgeicon(Figure58)
appearsinthelowerrightcornerofthescreen
astheregenerationprocesses.
g224403
Figure58
Note:WhiletheDPFregeneration
runs,theInfoCenterdisplaysthehigh
exhaust-temperatureicon.
9.Whentheenginecomputercompletesa
parkedorrecoveryregeneration,theInfoCenter
41

Table of Contents

Other manuals for Toro Groundsmaster 360

Related product manuals