ElectricalSystem
Maintenance
ElectricalSystemSafety
Disconnectthebatterybeforerepairingthe
machine.Disconnectthenegativeterminalrst
andthepositivelast.Connectthepositiveterminal
rstandthenegativelast.
Chargethebatteryinanopen,well-ventilated
area,awayfromsparksandames.Unplugthe
chargerbeforeconnectingordisconnectingthe
battery.Wearprotectiveclothinganduseinsulated
tools.
CheckingtheBattery
Condition
ServiceInterval:Every50hours
Important:Beforeweldingonthemachine,
disconnectthenegativecablefromthebatteryto
preventdamagetotheelectricalsystem.Also,
youmustdisconnecttheengine,InfoCenter,
andmachinecontrollersbeforeweldingonthe
machine.
Note:Keeptheterminalsandtheentirebatterycase
clean,becauseadirtybatterydischargesslowly.T o
cleanthebattery,washtheentirecasewithasolution
ofbakingsodaandwater.Rinsewithclearwater.
Coatthebatterypostsandcableconnectorswith
Grafo112X(skin-over)grease(ToroPartNo.505-47)
orpetroleumjellytopreventcorrosion.
LocatingtheFuses
Important:Ifyouareinstallinganauxiliary
accessorytothemachine,theonlyapproved
locationstosourcepowerareatthetraction-unit
fuseblock(Figure104)orthecab-fuseblock
(Figure106).Amaximumof10Aisavailablefrom
eitherlocation.ContactyourauthorizedToro
distributorforassistance.
Note:Shutofftheengineandremovethekeybefore
removingthefuses.
Thetraction-unitfuses(Figure100)arelocatedinthe
power-centerconsolebehindtheseat(Figure101).
Additionaltraction-unitfuses(Figure102)arelocated
ontherear,rightsideofthemachine(Figure103).
decal136-0006
Figure100
g031738
Figure101
1.Power-centerconsole2.Knobs
g033312
Figure102
74