hydraulicuid,replacethe
hydrauliclter(sooneriftheservice
intervalindicatorisintheredzone).
Every800hours—Ifyouarenotusingthe
recommendedhydraulicuidorhaveever
lledthereservoirwithanalternativeuid,
replacethehydrauliclter(sooneriftheservice
intervalindicatorisintheredzone).
Ifthehydraulicuidbecomescontaminated,contact
yourauthorizedTorodistributorbecausethesystem
mustbeushed.Contaminateduidlooksmilkyor
blackwhencomparedtocleanuid.
UseT ororeplacementlters(PartNo.86-6110forthe
leftsideofthemachineandPartNo.75-1310forthe
rightsideofthemachine).
Important:Usinganyotherltermayvoidthe
warrantyonsomecomponents.
1.Parkthemachineonalevelsurface,engagethe
parkingbrake,lowerthecuttingdeck,shutoff
theengine,andremovethekey.
2.Cleantheareaaroundthelter-mountingareas.
3.Placeadrainpanunderthelterandremove
thelter(Figure132).
4.Lubricatethenewltergasketandllthelter
withhydraulicuid.
5.Ensurethateachlter-mountingareaisclean
andscrewthelteronuntilthegasketcontacts
themountingplate;thentightenthelteran
additional1/2turn.
6.Fillthereservoirwithhydraulicuid;referto
CheckingtheHydraulicFluid(page86).
Important:Useonlythehydraulicuids
specied.Otheruidscouldcausesystem
damage.
7.Installthereservoirdipstickandcap.
8.Starttheengineanduseallofthehydraulic
controlstodistributehydraulicuidthroughout
thesystem.
Note:Also,checkforleaks,thenshutoffthe
engine.
9.Checktheuidlevelandaddenoughtoraise
theleveltotheFullmarkonthedipstick.
Note:Donotoverll.
CheckingtheHydraulic
LinesandHoses
ServiceInterval:Every2years
WARNING
Hydraulicuidescapingunderpressurecan
penetrateskinandcauseinjury.
•Seekimmediatemedicalhelpifuidis
injectedintoskin.
•Makesurethatallhydraulic-uidhoses
andlinesareingoodconditionandall
hydraulicconnectionsandttingsaretight
beforeapplyingpressuretothehydraulic
system.
•Keepyourbodyandhandsawayfrom
pinholeleaksornozzlesthateject
high-pressurehydraulicuid.
•Usecardboardorpapertondhydraulic
leaks.
•Safelyrelieveallpressureinthehydraulic
systembeforeperforminganyworkonthe
hydraulicsystem.
Inspectthehydrauliclinesandhosesdailyfor
leaks,kinkedlines,loosemountingsupports,wear,
loosettings,weatherdeterioration,andchemical
deterioration.Makeallnecessaryrepairsbefore
operatingthemachine.
InspectingtheHydraulic
SystemTestPorts
Thetestportsareusedtotestthepressureinthe
hydrauliccircuits.ContactyourauthorizedToro
distributororrefertotheToroServiceManualfor
assistance.
88