APPENDIX D
S7 Connection completion time-out
This register sets the time, in seconds, that the modem must wait before
hanging up because carrier is not detected. The timer is started when
the modem finishes dialing (originate), or goes off-hook (answer). In
originate mode, the timer is reset upon detection of an answer tone if
allowed by county restriction. The timer also specifies the wait for
silence time for the @ dial modifier in seconds. S7 is not associated with
the W dial modifier.
Range: 1-255
Default: 50
Units: seconds
S8 Comma pause time
This register sets the time, in seconds, that the modem must pause
when it encounters a comma (,) in the dial command string. In some
countries/regions, S8 will set both wait before dialing and comma pause
time.
Range: 0-255
Default: 2
Units: seconds
S11 DTMF dialing speed
This register determines the dialing speed which is prefixed for each
country/region.
Range: 50-255
Default: 95
Units: .001 seconds
S12 Escape guard time
This register sets the value (in 20 millisecond increments) for the
required pause after the escape sequence.
Range: 0-255
Default: 50
Units: .02 seconds