EasyManua.ls Logo

Toshiba ACE-tronics G9 ASD - Page 239

Toshiba ACE-tronics G9 ASD
297 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ACE-tronics G9 ASD Installation and Operation Manual 229
Traverse Selection (Not Used With the ACE-tronics G9 ASD)
Program Special Traverse
This parameter setting is used in the setup of the Traverse control mode of
operation and is used in conjunction with the discrete terminal activation of the
Traverse Permission Signal.
This parameter is used to enable the T
raverse function. The Traverse function
is activated via the discrete input terminal (see Table 7 on pg. 236).
See the Traverse Control Instruction Manual (P/N E6581337) for additional
information on this feature.
Settings:
Disabled
Enabled
Direct Access Number — F980
Parameter Type — Selection List
Factory Default Disabled
Changeable During Run — No
Traverse Acceleration Time (Not Used With the ACE-tronics
G9 ASD)
Program Special Traverse
This parameter setting is used in the setup of the Tr
a
v
erse control mode of
operation. This setting establishes the acceleration rate used during the
Traverse function.
See the T
raverse Control Instruction Manual (P/N E6581337) for additional
information on this feature.
Direct Access Number — F981
Parameter Type — Numerical
Factory Default 25.0
Changeable During Run — No
Minimum — 0.1
Maximum — 120.0
Units — Seconds
Traverse Deceleration Time (Not Used With the ACE-tronics
G9 ASD)
Program Special Traverse
This parameter setting is used in the setup of the Traverse control mode of
operation. This setting establishes the deceleration rate used during the
Traverse function.
See the T
raverse Control Instruction Manual (P/N E6581337) for additional
information on this feature.
Direct Access Number — F982
Parameter Type — Numerical
Factory Default 25.0
Changeable During Run — No
Minimum — 0.1
Maximum — 120.0
Units — Seconds
Traverse Step (Not Used With the ACE-tronics G9 ASD)
Program Special Traverse
This parameter setting is used in the setup of the Traverse control mode of
operation. This setting is used as a multiplier to establish the amount that the
frequency is increased or decreased while using the Traverse function.
See the T
raverse Control Instruction Manual (P/N E6581337) for additional
information on this feature.
Direct Access Number — F983
Parameter Type — N
umerical
Factory Default 10.0
Changeable During Run — No
Minimum — 0.0
Maximum — 25.0
Units — %