ACE-tronics G9 ASD Installation and Operation Manual 55
DBR OL (Overload) Trip — Displays the DBR Overload Trip value as a percentage of the Dynamic
Braking Resistor capacity.
DBR Load — D
isplays the DBR Load as a percentage of the Dynamic Braking Resistor capacity.
Feedback (Inst) — Provides a status of the Real Time Feedback in Hz.
Feedback (1 Second) — Provides a status of the 1-Second Averaging feedback in Hz.
Torque Displays the Output Torque as a percentage of the rated capacity of the ASD.
Torque Reference Displays the Torque Reference as a percentage of the maximum torque
available.
Torque Current Di
splays the torque-producing current value.
Excitation Current Displays the current value required to produce the excitation field.
PID Feedback — Provides a status of the PID Real Time Feedback in Hz.
Input Power — Displays the Input Power in Kilowatts (kW).
Output Power — Displays the Output Power in Kilowatts (kW).
Pattern Group Number Displays the active Pattern Run Group Number.
Pattern Cycle Number Displays the cycle number of the active Pattern Run Group.
Pattern Preset Displays the active Preset Speed being run of the active Pattern Run Group.
Pattern Time Displays the remaining time for the active Pattern Run Group.
RR — Displays the RR input value as a percentage of the full range of the RR value (potentiometer
input).
V/I — Displays the V/I input setting as a percentage of the full range of the V/I value.
Note: The isolated V/I input terminal may receive Current or Voltage to control the output
speed or the output torque. The input signal type must be selected at SW2 on the
ACE G9-120V-PCB.
The V input setting of SW2 is used for the 0 – 10 VDC analog input signal and the I
input setting of SW2 is used for the 0 – 20 mA analog input signal. Either may be used
as a frequency or torque command source. See parameter F201 for more information
on the setup of this terminal.
RX — Displays the RX input setting as a percentage of the full range of the RX value (±10 VDC input).
RX2 Option (AI1) — Displays the RX2 input setting as a percentage of the full range of the RX2 value.
Note: The RX2 function is available on the Expansion IO Card Option 1 option board
(P/N ETB003Z) only.
Trip Code Displays None if there are no errors, or displays one of the associated Fault Codes listed
in Table 15 on page 254 if there is an active Fa
ult (e.g., E = Emergency Off).