ADJUSTMENT
3 - 79
3
Duplex copying:
(1) Turn the power ON while pressing [0] and [5] simultaneously, key in [366] and then press the
[START] button.
(2) Enter the value.
If the leading edge (F) margin of the copy image is larger than the (E) margin of the chart,
enter a value smaller than the current one.
Note: Note:
Changing one value shifts the copy image by 0.1 mm.
If the leading edge (F) margin of the copy image is smaller than the (E) margin of the chart,
enter a value larger than the current one.
Note: Note:
Changing one value shifts the copy image by 0.1 mm.
(3) Press the [ENTER] button.
3.11.5 Adjustment of Horizontal Position
Note: Note:
Check if the image adjustment for the equipment is performed properly before this adjustment of
the RADF. Also, the RADF position and height shall be adjusted properly.
[A] Checking
Check the image using the chart (original) with a center line in the following procedure.
(1) Place the chart provided as an original with its face up on the original tray of the RADF.
(2) Press the [START] button.
(3) Fold the copy in half and check if the center line is misaligned.
[B] Adjustment
(1) Turn the power ON while pressing [0] and [5] simultaneously.
(2) Key in [358] and then press the [START] button.
If the center line of the copy image is shifted to the front side of the equipment, enter a value
larger than the current one.
Note: Note:
Changing one value shifts the copy image by 0.042 mm.
Fig. 3-109
If the center line of the copy image is shifted to the rear side of the equipment, enter a value
smaller than the current one.