ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 34
2.2.2 Input check (Test mode 03) (e-STUDIO352/353/452/453)
<Operation procedure>
Note: Note:
Initialization is performed before the equipment enters the test mode.
Fig. 2-3 Example of display during input check
Items to be checked and the condition of the equipment when the buttons [A] to [H] are highlighted are
listed in the following pages.
The status of each input signal can be checked by pressing the [FAX] button, and the digital keys in
the test mode (03).
[0][3]
[POWER]
[START]
[FAX]
[Digital keys]
[CLEAR]
(LCD ON)
[POWER] OFF/ON
(Exit)
[0][5]
[POWER]
[POWER]OFF/ON
(Exit)
[Digital key]
(Code)
[START]
()
Automatic
adjustment
([FAX])
(Test copy)
*[CANCEL] or [CLEAR]