3 - 4
3. Printer-specific Adjustments
(1) Enter setting mode [08]. Set "1" for code [9059].
During automatic calibration, the paper type can be selected and image quality control will be
automatically performed.
Value for 08-9059
Operation switching at calibration
(displaying of a paper selection menu during automatic calibration)
0 No paper selecting buttons display
1 Paper selecting buttons displayed. (For both Copy and Printer)
After setting the value, use the next procedure.
(2) Perform automatic calibration to correct variations in image density.
* [ADMIN] is selected from among the [CALIBRATION DISPLAY LEVEL] options by default. In other
words, an administrator is authorized to operate the automatic calibration. But the [USER] option can also
be selected to allow the user to operate it. Refer to the User Functions Guide for further information
regarding how to select the [CALIBRATION DISPLAY LEVEL] option.
* Use steps (a) through (l) to perform the automatic calibration.
(a) Press the [USER FUNCTIONS] button on the Control Panel to enter the "User Functions" menu.
(b) Press the [ADMIN] tab.
(c) Enter an administrator password of 6 to 10 digits. Press the [ENTER] button.
(d) Press the [GENERAL] button.
(e) Press the [CALIBRATION] button.
(f) Press the [PRINT] button.
(g) Press [DEFAULT] to set the default calibration setting, or [CALIBRATION] to adjust the calibration
setting.
* When you press [DEFAULT], the system maintains the default calibration setting for the selected
job type and returns to the previous screen.
* When you press [CALIBRATION], a chart is printed out and the calibration guide illustration is
displayed on the touch panel. Proceed to the next step.
(h) Place the printed chart face down on the original glass aligning it with its left rear corner, so that two
black rectangular marks are on the left side.
(i) Press the [START] button on the control panel.
* The calibration begins. Do not operate the equipment until the message “Scanning and calibrating”
disappears.
* If the chart is not properly placed, the message “Set chart correctly” is displayed on the touch panel.
In this case, return to step (h) and realign the chart.