EasyManua.ls Logo

Toshiba e-STUDIO657 - Page 347

Toshiba e-STUDIO657
754 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
e-STUDIO556/656/756/856
4
05/08 Mode Element
Sub
element
Item Subitem Code
Sub-
code
Details
Default
value
Acceptable
value
RAM Contents
Proce
dure
Servic
e UI
08
Setting
Mode
Process Fuser 2060
Threshold of low
temperature
environment control
7 0~11 M
The boundary temperature of the low and normal
temperature control can be set.
0: 0°C 1: 5°C 2: 9°C 3: 10°C 4: 12°C 5: 14°C 6: 15°
C 7: 16°C 8: 17°C 9: 18°C 10: 19°C 11: 20°C
1
08
Setting
Mode
Process Fuser 2084
Low-speed pre-
running setting at
recovery from Energy
Saving Mode
Refer to
contents
0~1 M
0: Performs prerunning 1: No pre-running
<Default value>
e-STUDIO556/656:
JPC: 1
Others: 0
e-STUDIO756/856: 0
1
08
Setting
Mode
Process Fuser
Pre-running period
end temperature
Pressure roller 2105 Low temperature 8 0~16 M
0: 100°C 1: 110°C 2: 120°C 3: 125°C 4: 130°C 5:
135°C 6: 140°C 7: 145°C 8: 150°C 9: 155°C 10:
160°C 11:165°C 12: 170°C 13: 175°C 14: 180°C 15:
185°C 16: 190°C
1
08
Setting
Mode
Process Fuser
Pre-running period
end temperature
Pressure roller 2117
Normal temperature /
Option installed
Refer to
contents
0~16 M
0: 100°C 1: 110°C 2: 120°C 3: 125°C 4: 130°C 5:
135°C 6: 140°C 7: 145°C 8: 150°C 9: 155°C 10:
160°C 11: 165°C 12: 170°C 13: 175°C 14: 180°C 15:
185°C 16: 190°C
<Default value>
e-STUDIO556/656:
TWD: 6
Others: 4
e-STUDIO756/856:
NAD/SAD: 6
Others: 4
1
08
Setting
Mode
Process Fuser
Low-speed pre-
running starting
temperature during
ready status
Pressure roller 2122
When options are
installed
16 0~16 M
0: 50°C 1: 55°C 2: 60°C 3: 65°C 4: 70°C 5: 75°C 6:
80°C 7: 85°C 8: 90°C 9: 95°C 10: 100°C 11: 105°C
12: 110°C 13: 115°C 14: 120°C 15: 125°C 16: 130°C
1
08
Setting
Mode
Process Fuser
Low-speed pre-
running stopping
temperature during
ready status
Pressure roller 2123
When options are
installed
2 0~9 M
0: 5°C 1: 10°C 2: 15°C 3: 20°C 4: 25°C 5: 30°C 6:
35°C 7: 40°C 8: 45°C 9: 50°C
1
08
Setting
Mode
Process Fuser
Switching timing into
low-speed pre-running
from start of ready
status
2130 Pressure roller 1 0~12 M
0: Switching disabled 1: 5 min. 2: 10 min. 3: 20 min.
4: 30 min. 5: 40 min. 6: 50 min. 7: 60 min. 8: 70 min.
9: 80 min. 10: 90 min. 11: 100 min. 12: 120 min.
1