e-STUDIO556/656/756/856
5
05/08 Mode Element
Item Subitem Code
Details
RAM Contents
Mode
running starting
temperature during
ready status
(When setting 08-
2130 is enabled)
contents
0: 50°C 1: 55°C 2: 60°C 3: 65°C 4: 70°C 5: 75°C 6:
80°C 7: 85°C 8: 90°C 9: 95°C 10: 100°C 11: 105°C
12: 110°C 13: 115°C 14: 120°C 15: 125°C 16: 130°C
<Default value>
e-STUDIO556/656:
JPC: 6
Others: 10
e-STUDIO756/856: 10
Mode
running stopping
temperature during
ready status
(When setting 08-
2130 is enabled)
0: +5°C 1: +10°C 2: +15°C 3: +20°C 4: +25°C 5:
+30°C 6: +35°C 7: +40°C 8: +45°C 9: +50°C
Mode
running starting
temperature during
ready status
(When setting 08-
2130 is enabled)
0: 50°C 1: 55°C 2: 60°C 3: 65°C 4: 70°C 5: 75°C 6:
80°C 7: 85°C 8: 90°C 9: 95°C 10: 100°C 11: 105°C
12: 110°C 13: 115°C 14: 120°C 15: 125°C 16: 130°C
Mode
running stopping
temperature during
ready status
(When setting 08-
2130 is enabled)
0: +5°C 1: +10°C 2: +15°C 3: +20°C 4: +25°C 5:
+30°C 6: +35°C 7: +40°C 8: +45°C 9: +50°C
Mode
mode(When thick
paper 2 is used)
The fusing efficiency level goes up during a continuous
printing (when Thick 3 is selected).
0: Disabled 1: Enabled
Mode
speed
0: Disabled 1: Enabled only for 5 minutes after
warming-up 2: Always enabled
Mode
speed
2243 Thick paper 1 0 0~2 M
0: Disabled 1: Enabled only for 5 minutes after
warming-up 2: Always enabled
Mode
speed
2244 Thick paper 2 0 0~2 M
0: Disabled 1: Enabled only for 5 minutes after
warming-up 2: Always enabled
Mode
speed
2245 Thick paper 3 0 0~2 M
0: Disabled 1: Enabled only for 5 minutes after
warming-up 2: Always enabled
Mode
start reeling cleaning
web
The equipment starts reeling the cleaning web every
time the specified number of sheets have been printed.
(= Setting value X 1 sheet)
Mode
portion of cleaning
web
0 0~1 M 0: Displayed 1: Not displayed 1