EasyManua.ls Logo

Toshiba P9 - Page 152

Toshiba P9
306 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
142 P9 ASD Installation and Operation Manual
Panel Torque Bias
Program Torque Torque Control
Once enabled at F341, this parameter establishes the torque bias setting to
which the setting of F342 will either add to or subtract from to produce the final
torque value used to carry out the Braking Mode Selection function of F341.
Direct Access Number — F343
Parameter Type — Numerical
Factory Default 100.00
Changeable During Run — Yes
Minimum — -250.00
Maximum — +250.00
Units — %
Panel Torque Gain
Program Torque Torque Control
Once enabled at F341, this parameter sets the sensitivity of the torque control
source selected at F342 for the Braking Mode Selection function of F341.
Direct Access Number — F344
Parameter Type — Numerical
Factory Default 100.00
Changeable During Run — Yes
Minimum — 0.00
Maximum — 100.00
Units — %
Release Time
Program Torque Torque Control
Once enabled at F341, this parameter sets the time that the brake will hold after
the requirements of the Braking Mode Selection function of F341 have been
met.
Direct Access Number — F345
Parameter Type — Numerical
Factory Default 0.05
Changeable During Run — Yes
Minimum — 0.00
Maximum — 2.50
Units — Seconds
Creeping Frequency
Program Torque Torque Control
Once enabled at F341, upon receiving a Stop command while running, this
parameter sets an output frequency to be provided for the duration of the time
setting of
F347.
Direct Access Number — F346
Parameter Type — Numerical
Factory Default 3.00
Changeable During Run — Yes
Minimum — F240 Setting
Maximum — 20.0
Units — Hz
Creeping Time
Program Torque Torque Control
Once the Creep function of F346 is activated, this parameter determines the
duration of activation of the Creep function.
Direct Access Number — F347
Parameter Type — Numerical
Factory Default 0.10
Changeable During Run — Yes
Minimum — 0.0
Maximum — 2.50
Units — Seconds
F343 F347